<LOGO>
FM Transmitter Measurement Report
Created: 2024-10-16 21-21-00
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.30 MHz 5/5, 73 dBuV NOSTALGI
Pilot RDS Phase Difference
6.1 kHz 3.2 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
12 kHz 65 kHz 10796 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
1,7 dBr 5,39 dBr 6,7 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"NOSTALGI" 6411 10 (Pop M) 1 0 1 7 --:--
RT
"Elamasi musiikkia. "
AF EON
92.7, 94.3, 99.5, 100.5 MHz -
FM Scope Max at: 65 kHz MIN: 12 kHz % above 76 kHz: 0,0000 Acquired: 2024/10/16 21.19.56 Total samples: 10796 Equivalent time: 0:08:59 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000 1500
FM Scope MAX: 6,7 dBr MIN: 1,7 dBr AVE: 5,39 dBr % above 12,2 dBr: 0,0 Last value: 6,3 dBr (2024/10/16 21.19.56) 21.06 21.08 21.10 21.12 21.14 21.16 21.18 0 50 100 Dev. MAX [kHz] 0 2 4 6 Pm [dBr]